News
Products
Company
Contact
Products
Catalog
Conventional
valves
Pressure
control valves
Check valves
Non-return valves
Subplate
mounting
Sandwich plate
Screw-in type
Shuttle valves
Line break
safty
Anti cavitation
Flow valves
Directional
control valves
Proportional valves
Manifold blocks
Services
Index/Search
Order Catalog
Non-return valves - Sandwich plate
Description
Type
Pmax
(press.)
Qmax
(flow)
check valve plate CETOP 3
(sandwich plate) in P
RZ-06S-P
(
IZ-110-200-00
)
350 bar
30 l/min.
check valve plate CETOP 3
(sandwich plate) in PD
RZ-06S-PD
(
IZ-110-201-00
)
350 bar
30 l/min.
check valve plate CETOP 3
(sandwich plate) in T
RZ-06S-T
(
IZ-110-202-00
)
350 bar
30 l/min.
check valve plate CETOP 3
(sandwich plate) in P+T
RZ-06S-P+T
(
IZ-110-203-00
)
350 bar
30 l/min.
check valve plate CETOP 3
(sandwich plate) in A
RZ-06S-A
(
IZ-110-204-00
)
350 bar
30 l/min.
check valve plate CETOP 3
(sandwich plate) in B
RZ-06S-B
(
IZ-110-205-00
)
350 bar
30 l/min.
check valve plate CETOP 3
(sandwich plate) in A+B
RZ-06S-A+B
(
IZ-110-206-00
)
350 bar
30 l/min.
check valve plate CETOP 5
(sandwich plate) in P
RZ-10S-P
(
IZ-110-400-00
)
350 bar
50 l/min.
check valve plate CETOP 5
(sandwich plate) in T
RZ-10S-T
(
IZ-110-401-00
)
350 bar
50 l/min.
check valve plate CETOP 5
(sandwich plate) in P+T
RZ-10S-P+T
(
IZ-110-402-00
)
350 bar
50 l/min.
check valve plate CETOP 5
(sandwich plate) in A
RZ-10S-A
(
IZ-110-403-00
)
350 bar
50 l/min.
check valve plate CETOP 5
(sandwich plate) in B
RZ-10S-B
(
IZ-110-404-00
)
350 bar
50 l/min.
check valve plate CETOP 5
(sandwich plate) in A+B
RZ-10S-A+B
(
IZ-110-405-00
)
350 bar
50 l/min.
check valve plate CETOP 7
(sandwich plate) in P
RVZ-16S-P
(
IZ-110-500-00
)
350 bar
140 l/min.
check valve plate CETOP 7
(sandwich plate) in T
RVZ-16S-T
(
IZ-110-501-00
)
350 bar
140 l/min.
check valve plate CETOP 7
(sandwich plate) in A
RVZ-16S-A
(
IZ-110-502-00
)
350 bar
140 l/min.
check valve plate CETOP 7
(sandwich plate) in B
RVZ-16S-B
(
IZ-110-503-00
)
350 bar
140 l/min.
check valve plate CETOP 8
(sandwich plate) in P
RVZ-25.-P
(
IZ-110-600-00
)
350 bar
240 l/min.
check valve plate CETOP 8
(sandwich plate) in T
RVZ-25.-T
(
IZ-110-601-00
)
350 bar
240 l/min.
check valve plate CETOP 8
(sandwich plate) in T+Y
RVZ-25A-T+Y
(
IZ-110-602-00
)
250 bar
240 l/min.
check valve plate CETOP 8
(sandwich plate) from A to P
RVZ-25A-AP
(
IZ-110-603-00
)
250 bar
240 l/min.
check valve plate CETOP 8
(sandwich plate) from B to P
RVZ-25A-BP
(
IZ-110-604-00
)
250 bar
240 l/min.
check valve plate CETOP 3
(sandwich plate) in P w.port in D
RMZ-06S-PD
(
IZ-120-200-00
)
350 bar
60 l/min.
check valve plate CETOP 3
(sandwich plate) in P w.port in D
RCZ-06S-PD
(
IZ-120-250-00
)
350 bar
60 l/min.
check valve plate CETOP 5
(sandwich plate) in P w.port in D
RMZ-10S-PD
(
IZ-120-400-00
)
350 bar
60 l/min.
check valve plate CETOP 5
(sandwich plate) in P w.port in D
RCZ-10S-PD
(
IZ-120-450-00
)
350 bar
60 l/min.
pilot op. check valve CETOP 3
(sandwich plate) in A
RHEZ-06S-A
(
IZ-130-200-00
)
320 bar
60 l/min.
pilot op. check valve CETOP 3
(sandwich plate) in B
RHEZ-06S-B
(
IZ-130-201-00
)
320 bar
60 l/min.
pilot op. check valve CETOP 3
(sandwich plate) in A+B
RHEZ-06S-A+B
(
IZ-130-202-00
)
320 bar
60 l/min.
pilot op. check valve CETOP 5
(sandwich plate) in A+B
KR-012
(
IZ-130-400-00
)
350 bar
100 l/min.
pilot op. check valve CETOP 5
(sandwich plate) in A
KR-013
(
IZ-130-401-00
)
350 bar
100 l/min.
pilot op. check valve CETOP 5
(sandwich plate) in B
KR-014
(
IZ-130-402-00
)
350 bar
100 l/min.
pilot op. check valve CETOP 3
(sandwich plate) in A (vented to T)
RHEVZ-06S-A/..
(
IZ-135-250-00
)
350 bar
60 l/min.
pilot op.check valve from P CETOP 3
(sandwich plate) in A
REMZ-06A-A/...
(
IZ-140-200-00
)
250 bar
60 l/min.
pilot op.check valve from P CETOP 3
(sandwich plate) in B
REMZ-06A-B/...
(
IZ-140-201-00
)
250 bar
60 l/min.
pilot op.check valve from P CETOP 3
(sandwich plate) in A+B
REMZ-06A-A+B/..
(
IZ-140-202-00
)
250 bar
60 l/min.
pilot op.check valve from P CETOP 3
(sandwich plate) in A
RECZ-06A-A/..
(
IZ-140-250-00
)
250 bar
60 l/min.
pilot op.check valve from P CETOP 3
(sandwich plate) in B
RECZ-06A-B/..
(
IZ-140-251-00
)
250 bar
60 l/min.
pilot op.check valve from P CETOP 3
(sandwich plate) in A+B
RECZ-06A-A+B/..
(
IZ-140-252-00
)
250 bar
60 l/min.